Configuration

7-94

48XX/49XXSHB0399

7.6.4

S-shaped ramp function generator characteristic

For the ramp generator of the main set-value you can select two different
characteristics under C134:

( linear characteristic for all accelerations which require a constant

acceleration

( S-shaped characteristic for all accelerations which require a shock-free

acceleration.

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C012

Acceleration
time T

ir

for

main
set-value

0.00s 0.00 s

{0.01 s}

1 s

1 s

{0.1 s}

10 s

10 s

{1 s}

100 s

100 s

{10 s}

990 s

Time refers to 0...n

max

C013

Deceleration
time T

if

for

main
set-value

0.00s 0.00 s

{0.01 s}

1 s

1 s

{0.1 s}

10 s

10 s

{1 s}

100 s

100 s

{10 s}

990 s

Time refers to 0...n

max

C131* Ramp

function
generator
STOP

0

-0-

Enable ramp function generator

-1-

Stop ramp function generator

If ramp function generator STOP (main
setpoint) is enabled via terminal, C131 is
for display only.

C132* Ramp

function
generator
input = 0

0

-0-

Enable mains setpoint at RFG input

-1-

Ramp function generator input = 0

C134* Ramp

function
generator
characteristic

0

-0-

Linear characteristic

-1-

S-shaped characteristic

C182* T

i

time of the

s-shaped
ramp function
generator

20.0 s 0.01 s

{0.01 s}

1 s

1s

{0.1s}

10s

10s

{1s}

50s

T

i

time for the S-shape ramp function

generator of the main set-value

Depending on the operating mode, the functions RFG stop (C131) and ramp
function generator input = 0 (C132)can be controlled and used for other switching
via the keypad, LECOM interface or freely assignable digital input terminals.

Note!

With setting controller inhibit, the signal at the RFG output jumps to the value = 0.
If the controller is enabled again, the set-value at the RFG output accelerates from
the actual speed to the speed set-value.

7.6.5

Actual speed filter

The actual speed circuit is equipped with a PT1 filter which is activated under
C198. The filter can be used to reduce mechanical resonances. The filter should
only be used in configurations without superimposed phase control circuits.
(C254=0).