Configuration
7-78
48XX/49XXSHB0399
7.5.5
Absolute value generator
Purpose
Bipolar signals can be converted into unipolar signals.
Parameter setting
4900Str061
C 1 4 6 / C 1 4 7
C 1 4 5 / C 1 4 6
C 6 6 0
C 1 4 5 / C 1 4 6
I n p u t
O u t p u t 1
O u t p u t 2
FIG 7-34
Absolute value generator
1. Input
With the function ”freely assignable analog inputs” each input can be assigned to
a ”terminal signal” from the table in C145.
2. Outputs
With the function ”freely assignable analog inputs” the outputs can be assigned to
the targets listed under C146.
3. Function
The absolute value of the input signal is generated.
Code
Name
Possible settings
Code
Name
Lenze Selection
Info
C660*
Input,
absolute
value
generator
0 %
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
Display parameter only