7-130

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

C112*

¤ Input selection:

Freely
assignable
digital input

1

-1-

digital input X2/E1

-2-

digital input X2/E2

...
-5-

digital input X2/E5

The digital inputs E1..E5 are freely
assignable with the functions under C113.
Each function can only be assigned to one
input. Exceptions:

l

C113 = -20- : max. 2 dig. inputs

l

C113 = -1-, -2-, -40-: max. 4 dig.
inputs (binary coded selection of max.
1, 3, 7 or 15 additional T

i

times or

setpoints).

Assignment of functions:
1.Select input under C112.
2.Assign function under C113.
3.Determine polarity under C114.
4.Determine priority under C115.

[C113*] Function for

C112

-0-

No function

-1-

Enable additional T

i

times

-2-

Enable JOG setpoint (X4/E4, E5)

-3-

TRIP reset (X2/E2)

-4-

TRIP set (X2/E1)

-6-

Switch-off additional setpoint (X4/E3)

-7-

Switch-off I-component of the n-controller

-9-

Ramp function generator stop

-10-

Ramp function generator zero

-16

Motor potentiometer deactivated

-17

Motor potentiometer down

-18

Motor potentiometer up

-20

Select parameter set

-21

Load parameter set

-30-

Deactivate process controller

-31-

Switch-off I-component of the process
controller

-32-

Set the process controller to 0

-40-

Enable fixed setpoint

[C114*] Polarity for

C112

0

-0-

Input HIGH active

-1-

Input LOW active

[C115*] Priority for C112

-0-

Terminal function not active, if terminal
control is switched-off under C001.
(X2/E4, E5)

-1-

Terminal function remains active, if terminal
control is switched-off under C001.
(X2/E1, E2, E3)

C116*

¤ Input selection:

Freely
assignable
digital output

1

-1-

FDO 1

-2-

FDO 2

...
-12-

FDO 12

-13-

Relay output X3/K11, X3/K14

The digital outputs FDO1..FDO12 and the
relay output X3/K11, X3/K14 are freely
assignable with the functions under C117.
Multiple assignment is possible.
The outputs FDO1...FDO5 are assigned to
the terminals X3/A1...X3/A5.
FDO6...FDO12 can only be accessed via
LECOM.
Assignment of functions:
1.Select output under C116.
2.Assign function under C117.
Only for FDO1...FDO5, relay output:
3.Determine polarity under C118.
4.Determine signal delay under C128.