7-5

48XX/49XXSHB0399

9

5

2

1

10 kW (lin.)

S3/2

+ 10 V Ref.

V

= + 10 ... 0 V

Iset

min

max

4900Str029

FIG 7-2

Connection diagram for external torque reduction via potentiometer or master voltage

Note!

The terminal input is inverted and assigned with 100 % I

max

to reduce the wiring

for standard applications without external torque limitation.

For torque limit inputs (e. g. via master frequency), the function C047 = 100% -
|terminal (1,2)| can be changed to function C047 = |terminal (X5)|.

Code

Name

Possible settings

Lenze Selection

Info

C282*

¤ Function

for C047

0

-0-

Function C047 = 100% - |input source|

-1-

Function C047 = |input source|