C392 field current set-value

Note!

The field current cannot be reduced more than to the minimum field current set
under C231. If the controller is in field-weakening operation, this range cannot be
left by setting a higher field current set-value.

Display of the field current set-value.The figure 2

14

= 16384 corresponds to 100%

of the rated value under C083. The field current set-vlaue can be assigned to a
process input word so that the set-value can be controlled via the fieldbus system.

C393 additional set-value

Display of the additional set-value for the speed controller. The figure 2

14

= 16384

corresponds to 100% of the maximum additional set-value. The information is the
same as under C049.

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C380*

n

set

speed

-16384

{1}

16384

High precision set-value input:
16384

Ÿ 100%under C046

Input only via interface

C381*

n

set

at

n controller

-32767

{1}

32767

High precision set-value display:
Input of the speed controller
16384

Ÿ 100%under C050.

Input only via interface.

C382*

Actual
speed

-32767

{1}

32767

High precision display: actual speed value
16384

Ÿ n

max

under C011.

Input only via interface.

C387*

Torque limit

-16384

{1}

16384

High precision torque set-value input:
16384

Ÿ 100%under C047.

Input only via interface.

C388*

Torque
setpoint

-16384

{1}

16384

High precision torque set-value display:
16384

Ÿ 100%under C056.

Input only via interface.

C391*

Actual
phase

0

{1}

65535

High precision display of the actual phase
value if resolver or incrmental encoder
operate as feedback system:
16384

Ÿ 360• Ÿ 1 revolution

Input only via interface.

C392*

Field
current
set-value

0

{1}

16384

High precision display of the field current
set-value:
16384

Ÿ I

Frated

under C083.

Input only via interface.

C393*

Additional
set-value

-16384

{1}

16384

High precision additional set-value display:
16384

Ÿ 100%under C049.

Display only via interface.