Installation – Lenze EDS4900U-REG User Manual

Page 72

Advertising
background image

Installation

4-34

48XX/49XXSHB0399

4900Str022

l

l

L 1

L 2

L 3

P E

2

3

1 0

1 1

9

8

1 2

1

1 4

1 3

L

7

5

4

6

FIG 4-24

Part of the CE-typical drive system with 4X08/4X09 on a mounting plate

1

Connection mains fuse

2

Connection fan supply L1/N

3

RFI filter

4

Armature fuses

5

Screened signal cables

6

Metal plug-in casing connected to screen or Lenze system cable

7

Uncoated surface for screen connection

8

Mains choke field supply

9

Line protection fuses for field supply

10

Motor connection with screened cable for act. value encoder

11

Commutating choke

12

PE connection

13

RFI filter

14

Uncoated, bare metal contact surfaces