Configuration
7-108
48XX/49XXSHB0399
7.8
Parameter setting
( With the parameter setting of the controller you can adapt the drive to your
application.
( The complete parameter set is organized in codes which are consecutively
numbered and start with ”C” (chapter 7.9).
( It is possible to save the parameter set for an application.
- Four parameter sets are available, so that the controller can be easily
switched from one application to another.
- The parameter sets 1, 3 and 4 are factory set when delivered. Parameter
set 2 is set for an unwinder with diameter precontrol.
7.8.1
Ways of parameter setting
( It is possible to select a code, to change the parameters and transfer the
changes to the controller, via
- the operating unit of the controller
- LECOM interfaces
These Operating Instructions only describe the change of parameters via the
operating unit.
The description of parameter setting via LECOM interfaces or fieldbus systems can
be obtained from the corresponding Operating Instructions.