Configuration – Lenze EDS4900U-REG User Manual

Page 230

Advertising
background image

Configuration

7-139

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

C273*

Digital/
analog
conversion 2

-16384

{1}

16384

Input: Value for the conversion into an
analog signal is to be entered via the
monitor outputs X4/62, X4/63 or digital
frequency output X8. Input only via
interfaces.

C280*

¤ Additional

setpoint on/off

0

-0-

Additional setpoint is on

-1-

Additional setpoint is off

C282*

¤ Function for

C047

0

-0-

Function C047 = 100% - [input source]

-1-

Function C047 = [input source]

C285*

Limitation of
rate of rise

40

1

{1}

1000

Limitation of rate of rise at the armature
current controller input. Time:

-I

Amax

to + I

Amax

= C285

ô t

15°electr.

C286*

Upper limit of
the speed
setpoint

180%

-100.0 %

{0.1 %}

+ 100.0 %

-180 %

{1 %}

+ 180 %

Upper limit of the speed setpoint for C050
C286 must be higher than C287!

C287*

Lower limit of
the speed
setpoint

-180% -100.0 %

{0.1 %}

+ 100.0 %

-180 %

{1 %}

+ 180 %

Upper limit of the speed setpoint for C050
C287 must be smaller than C286!

C310*

Speed
dependent
current
limitation
Limit value 1

100%

0.0 %

{0.1 %}

+ 100.0 %

Valid for speed under C313
C310 must be higher than C311!

C311*

Speed
dependent
current
limitation
Limit value 2

100%

0.0 %

{0.1 %}

+ 100.0 %

Valid for speed under C314
C311 must be smaller than C310!

C312*

n

0

Speed
dependent
current
limitation

3000

rpm

0 rpm

{1 rpm}

5000 rpm

Act. speed threshold (current limitation),
condition: n

1

> n

0

C313*

n

1

Speed
dependent
current
limitation

4000

rpm

0 rpm

{1 rpm}

5000 rpm

Act. speed threshold for limit value 1
condition: n

2

> n

1

> n

0

C314*

n

2

Speed
dependent
current
limitation

5000

rpm

0 rpm

{1 rpm}

5000 rpm

Act. speed threshold for limit value 2
condition: n

2

> n

1

> n

0

C316*

Reduced field
current

20 %

0 % I

Frated

{1 % I

Frated

} 100 % I

Frated

Reference: I

Frated

(C083)

With 0%, the pulses of the field controller
are inhibited.

C317*

Time delay for
the reduced
field current

60 s

0.0 s

{0.1 s}

10 s

10 s

{1 s}

100 s

100 s

{10 s}

3600 s

Time which is required to activate the
reduced field current after inhibiting the
controller.

C318*

¤ Activate field

current
reduction

0

-0-

Field current reduction function is off

-1-

Field current reduction function is on

C319*

Actual V

p

of the

n- controller

1

{1}

1000

Display: Actual gain factor of the n-
controller (important for n-controller
adaption)