Installation – Lenze EDS4900U-REG User Manual

Page 61

Advertising
background image

Installation

4-23

48XX/49XXSHB0399

Pin assignment of socket X5/X9:

Pin

1

2

3

4

5

6

7

8

9

Signal

B

A

A

VE9

GND

Z

Z

LC

B

Pin 8, LC (

¥)

- For encoders without lamp control, assign +5 V...+30V. Otherwise, the

controller will indicate fault ”Sd3” or ”Sd4”.

Pin 4, VE9

- Is connected to the terminal of the external incremental encoder supply

X4/VE9.

90 FE

-

+

GND

X5, X9 Pin 4

X4

VE9

4900Str017

FIG 4-17

Connection of the incremental encoder supply

VE9

External supply for incremental encoder to X5/X9

90

Internal ground GND

FE

Functional earth

4.3.6

Change of the direction of rotation in 2Q operation

In 2Q operation (controller 48XX or C180 = -1-), only one thyristor bridge of the
controller is active, i.e. the output terminal A can only carry positive voltage referred
to terminal B, on the condition that no active loads occur.

The direction of rotation of the motor is determined by the connection of the
armature cable to A and B and of the field cable to I and K. If the opposite direction
of rotation is required, take the following steps (depending on the actual value
feedback system):

Act. speed feedback system

Direction of rotation changed by:

Additional measures

Armature voltage

None

Tacho

Exchange connection:

l

Terminals A and B

Connection tacho signal exchange term. 3
and 4

Resolver

l

Terminals A and B

or

l

Terminals I and K

Signal cable resolver
exchange track + sin and -sin

Incremental encoder

l

Terminals I and K

Invert act. speed sgnal via
C205 / C027