7.5.8

Addition

Purpose

The controller provides two addition facilities with three inputs each. Here, analog
signals can be added or subtracted.

Parameter setting

4900Str066

C 1 4 6 / C 1 4 7

C 1 4 5 / C 1 4 6

C 6 1 0

C 1 4 5 / C 1 4 6

± 2 0 0 %

+

+

+

-

C 1 4 6 / C 1 4 7

C 6 1 1

C 1 4 6 / C 1 4 7

C 6 1 2

I n p u t 1

O u t p u t 1

O u t p u t 2

I n p u t 2

I n p u t 3

FIG 7-39

Addition 1

4900Str067

C 1 4 6 / C 1 4 7

C 1 4 5 / C 1 4 6

C 6 1 4

C 1 4 5 / C 1 4 6

± 2 0 0 %

+

+

+

-

C 1 4 6 / C 1 4 7

C 6 1 5

C 1 4 6 / C 1 4 7

C 6 1 6

I n p u t 1

O u t p u t 1

O u t p u t 2

I n p u t 2

I n p u t 3

FIG 7-40

Addition 2

1. Input

With the function ”freely assignable analog inputs” each input can be assigned to
a ”terminal signal” from the table in C145. If signals are assigned to the inputs, the
input codes are for display only. If the inputs are not assigned, constant values can
be assigned via the input codes. These values can also be stored via C003.

2. Outputs

With the function ”freely assignable analog inputs” the outputs can be assigned to
the targets listed under C146.

3. Function

Input 1 is added to input 2. Input 3 is subtracted from the calculated result. Then,
the value is limited to

–200%.