Configuration – Lenze EDS4900U-REG User Manual

Page 127

Advertising
background image

Configuration

7-36

48XX/49XXSHB0399

Adaptation of the signal at the digital frequency output X8

If another signal than stated in the basic configuration (C005) is assigned, the
output frequency is adjusted via code C108.

Configurat
ion

Basic assignment

Adaptation of the output
frequency with ...

Notes

C005

C026 if
C025 = -13-

C030

C108

-10-, -40-

n

act

from C382

-

-

active

-11-, -41-

n

act

from C382

-

-

active

-12-, -42-

n

act

from C051

Selection
possible

-

-

The rotor zero position, which depends on
the resolver, is output on the zero track.

-13-, -43-

n

act

from C051

-

-

-

The encoder constant is only by the
incremental encoder used (hardware). A
zero track is only output if it is provided by
the incremental encoder.

-5x-

n

set

from C050

-

Selection
possible

-

The output signal is normalized to the
number of pulses of the incremental
encoder. A zero track will not be output.

-6x-

n

set

from C050

-

-

-

At the output X8 the signal from X9 is
directly output (electrically buffered). A zero
track is only output, if it is connected to
input X9.

-72-

n

set

from C050

-

Selection
possible

-

The output signal is normalized to the
number of pulses of the incremental
encoder. The corresponding encoder
constant can only be set under C030. The
gain can be set via C027 and C028 of the
input X5 (C025 = -10-). A zero track will
not be output.

The sign ”-” means that a change does not influence the output frequency.

Show/Hide Bookmarks