Troubleshooting and fault elimination

8-3

48XX/49XXSHB0399

8.2

Fault analysis with the history buffer

With the history buffer, faults can be traced. The fault messages are stored in the
history buffer in the order of their occurrence.

8.2.1

Structure of the history buffer

( The history buffer has eight memory locations, which can be retrieved

- under C065, C066 and C067 at the operating unit

- via the LECOM interface under codes C161 to C168 for TRIP messages.

( The first memory location is written only after the elimination or

acknowledgement of the active fault. The eighth from last fault is eliminated
in the history buffer and can no longer be read.

( The memory locations 1-8 contain information about the last to eighth from

last fault.

Code

C0168

C063

Active message

C066

Active warning

C067

Active TRIP

C161

Memory location 1

C162

Memory location 2

C163

Memory location 3

C164

Memory location 4

C165

Memory location 5

C166

Memory location 6

C167

Memory location 7

C168

Memory location 8

Show/Hide Bookmarks