Configuration – Lenze EDS4900U-REG User Manual

Page 226

Advertising
background image

Configuration

7-135

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

C148

Additional
torque value 1

0

-100.0 % M

max

{0.1%}

+ 100.0 % M

max

-200 % M

max

{1%}

+ 200 % M

max

Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
opera tion. Armature setting range: 100 %
M

max

correspond to 100 % I

max

(C022,

C023)

C149

Additional
torque value 2

0

-100.0 % M

max

{0.1%}

+ 100.0 % M

max

-200 % M

max

{1%}

+ 200 % M

max

Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
opera tion. Armature setting range: 100 %
M

max

correspond to 100 % I

max

(C022/C023)

C151*

FDO
Status

Bit

Free digital output

0

FDO 1

...
11

FDO 12

12

Relay output

C151 indicates the states of the digital
outputs as decimal or binary values. The
polarity reversal under C118 is not
considered.

[C180*] 4Q/2Q

operation

-0-

4Q operation (49XX)

-1-

2Q operation (48XX)

Important for controller type 48XX:
Controllers must only be operated with
C180 = -1-!
Fault PR sets C180 = -0-. It is absolutely
necessary to set C180 = -1- before
commissioning.

C182*

T

i

time of the

S-shape
ramp function
generators

20.0 s 0.01 s

{0.01s}

1 s

1s

{0.1s}

10s

10s

{1s}

50s

T

i

time for the S-shape ramp function

generator of the main setpoint

C183

Origin of
controller inhibit

Display

Origin of ctrl inhibit

Terminal or term.

Terminal

Keypad or kp

Keypad (STP key)

LECOM1 or L1

LECOM1 interface

Aut.int. (AIF)

Automation / fieldbus interface

(module, InterBus, PROFIBUS, ...)

oth. src. Other source
or o.s. Release: TRIP or message

Information: C065, C067

Display: Source which has inhibited the
controller

C185

Motor power

-500.0 kW

{0.1 kW}

500.0 kW

Display: actual motor power

C186

Motor torque

-999 Nm

{1 Nm}

999 Nm

Display: actual motor torque

C187

Field current
setpoint

0.00 A

{0.01 A}

50.0 A

Display: actual field current setpoint

C188

Actual field
current

0.00 A

{0.01 A}

50.0 A

Display: actual field current value

C189

Mains
frequency

0.0 Hz

{0.1 Hz}

100.0 Hz

Display: actual mains frequency

C190*

¤ Arithmetic

block 1

1

-0-

Output = C046

-1-

Output = C046 + C049

-2-

Output = C046 - C049

-3-

Output = C046

¼ C049

-4-

Output = C046 / |C049|

-5-

Output = C046 / (100% - C049)

C191*

¤ Arithmetic

block 2

1

-0-

Output = C338

-1-

Output = C338 + C339

-2-

Output = C338 - C339

-3-

Output = C338

¼ C339

-4-

Output = C338 / |C339|

-5-

Output = C338 / (100% - C339)