Configuration

7-19

48XX/49XXSHB0399

C072 K

dn

speed controller

For an improved starting behaviour of high-level controls, it is possible to set a
differential component in the speed controller. The factor indicated refers to the
proportional gain set under C070.

7.1.4

Offset and gain adjustment

( With these functions, the connected analog encoders can be adapted.
( In default setting, the offset voltages of the analog channels are adjusted.
( The offset voltages are not overwritten when loading the default setting.
( Carry out the offset adjustment before adjusting the gain.

Offset adjustment

1. Apply signal 0 V to the input to be adjusted.

2. Select the corresponding analog input under C025.

3. Set the offset correction under C026 (internal display = 0).

Input

Display code

Meaning (default setting)

X1/1, 2
X1/3, 4
X1/6
X1/8

C047
C051
C049
C046

Torque limitation
Actual value at C005 = -11-, -41-
Additional setpoint
n

set

Gain adjustment

1. Apply the set-value, to which the internal display is to be adjusted, to the

input to be adjusted.

2. Select the corresponding analog input under C025.

3. Select the signal gain under C027 or C029 such that the internal display

matches the set-value selection.

Note!

For adjustment of the actual-value input see chapter 7.1.2