2 components of the ce-typical drive system, 3 measures required, Installation – Lenze EDS4900U-REG User Manual

Page 68

Advertising
background image

Installation

4-30

48XX/49XXSHB0399

4.4.2

Components of the CE-typical drive system

System component

Specification

Controller

4800/4900 DC controllers

RFI filter

For data and filters see chapter 13.4

Mains choke

For assignment and technical data see chapter 13.2

Armature and field cable

Unscreened power cable
Rated max. length: 50m

Control cables

Screened signal cable type LIYCY

Encoder cable for digital frequency

Lenze system cable or screened signal cable, twisted in pairs, tin plated E-CU braid
with 75% optical overlay

Encoder cable for resolver

Lenze system cable type EWLR or screened signal cable, twisted in pairs, tin plated
E-CU braid with 75% optical overlay

Motor

Separately excited DC motor
Lenze series MGFQ, MGFR or similar

Accessories

InterBus module 2110IB
Profibus module 2130IB

Controller, RFI filter and mains choke are mounted on the same assembly board
inside a standard control cabinet.

4.4.3

Measures required

Control cabinet assembly board

( For HF grounding, only use mounting plates with an excellent conductive

surface (e.g. zinc-coated surface).

( If you use mounting plates with badly conductive surfaces (e.g. painted,

anodized, yellow passivated):

- Remove the paint or coating from the contact surface of the mains filters,

controllers, and screen connections, to provide a large and conductive
connection.

( When using several mounting plates, connect them with a surface as large

as possible (e.g. using copper bands).

( Connect the controller, RFI filter and mains choke to the grounded

mounting plate with a surface as large as possible.

Power connection

( Avoid unnecessarily long cables
( Ensure the separation of motor cable and signal or mains cable.
( Ensure separation of unscreened and screened cables (distance > filter

length)

( Ensure a distance as short as possible between the conductors

(single-cores)

( Both ends of unused cores should be connected to ground/PE.