Selection aid – Lenze EDS4900U-REG User Manual
Page 297
Advertising
Selection aid
15-5
48XX/49XXSHB0399
Parameter setting
Code
Input
Description
Input according to motor nameplate
C083
xxx A
Rated field current
C084
xxx ms
Armature-time constant
C088
xxx A
Rated motor current
C090
xxx V
Rated motor voltage
Input of current limits
C022, C023
xxx A
Maximum motor current
Enter controller configuration
C000
-2-
Extended code set
C005
-12-
Speed control with resolver feedback
Adjustment of speed controller
C011
xxxx rpm
Max. max. speed
Application parameters
C019
xxxx rpm
Set threshold n
act
= 0
C070
V
pn
At high inertia, adapt n - controller gain V
pn
Save parameter
C003
Save parameter set
Show/Hide Bookmarks
Advertising