Configuration

7-39

48XX/49XXSHB0399

7.3

Digital frequency coupling

General description of the system

The digital frequency coupling described here enables a digital set-value
transmission and evaluation between a set-value source and one or more
controllers. The transmission path can be used as bar or cascade for:

( Phase-synchronous running
( Speed-synchronous running
( Speed-ratio synchronism or
( Position controls with drift-free standstill
In every controller, the set-value can be evaluated with a factor and output with
a gain at the corresponding digital frequency output.

The digital frequency coupling is a pure digital set-value transmission with all of
its advantages:

( drift-free
( extremely precise
( increased noise immunity
Therefore, three configurations are offered:

( Master, C005 = -52-, -53-
( Slave for digital frequency bar, C005 = -62-, -63-
( Slave for digital frequency cascade, C005 = -72-

Set-value conditioning

In the set-value branch, the speed and phase set-values are processed as
absolute values.

Gearbox factors (C032 and C033)

The evaluation factors C032 and C033 are in the set-value channel of the
corresponding drive (slave). They are used to set the gearbox factor.

Setting range of the factors:

( C032 from -3.2767 to +3.2767
( C033 from +0.0001 to +3.2767.
The quotient is limited to max.

–32767.