Selection aid – Lenze EDS4900U-REG User Manual

Page 304

Advertising
background image

Selection aid

15-12

48XX/49XXSHB0399

Parameter setting

Code

Input

Description

Input according to motor nameplate

C083

xxx A

Rated field current

C084

xxx ms

Armature-time constant

C088

xxx A

Rated motor current

C090

xxx V

Rated motor voltage

Freely assignable analog inputs

C145

-4-

Input selection term. 8

C146

-15-

Arithmetic block2 input 1

C145

-3-

Input selection term. 6

C146

-16-

Arithmetic block2 input 2

C145

-10-

Input selection arithmetic block output

C146

-1-

Main set-value C046

C145

-9-

Input selection process controller output

C146

-3-

Additional set-value C049

C145

-1-

Input selection term. 1.2

C146

-7-

Actual process controller value

Freely assignable digital inputs

C112

-3-

Input selection E3

C113

-32-

Process controller evaluation

C112

-5-

Input selection E5

C113

-31-

Process controller I component off

Arithmetic block

C191

-4-

Output = input 1 / input 2

Convert distance

@ diameter

C025

-3-

Input selection term. 6

C026

Offset for distance a = -xxx mV

C027

2.000

Evaluation for diameter

Adjustment of speed controller

C011

xxxx rpm

Enter max. speed

C025

-2-

Select adjustment at terminals 3 and 4

C029

n

act

Adjust speed

process controller

C330

xxx %

Select position set-value

C331

xxx %

Evaluation of process controller output

Application parameters

C022, C023

xxx A

Maximum motor current

C019

xxxx rpm

Set threshold n

act

= 0

C070

V

pn

At high inertias, adapt n - controller gain

C222

V

pp

Optimise process controller

Save parameter

C003

Save parameter set

Show/Hide Bookmarks

Advertising