Selection aid – Lenze EDS4900U-REG User Manual

Page 301

Advertising
background image

Selection aid

15-9

48XX/49XXSHB0399

Parameter setting

Code

Input

Description

Input according to motor nameplate

Master and slave

C083

xxx A

Rated field current

C084

xxx ms

Armature-time constant

C088

xxx A

Rated motor current

C090

xxx V

Rated motor voltage

Input of current limits

Master and slave

C022, C023

xxx A

Maximum motor current

Enter controller configuration

Master and slave
C000

-2-

Extended code set

C005

-11-

Speed control with tacho feedback

Master
C110

-1-

Input selection term. 62

C111

-25-

Monitor output ’M

set

Adjustment of speed controller

Master and slave
C011

xxxx rpm

Select max. speed

C025

-2-

Select adjustment at terminals 3 and 4

C029

n

act

Adjust speed

Slave
C071

9999 ms

T

nn

, no I component

C025

-3-

Select adjustment at terminal 6

C027

Select weighting factor for act. speed influence divided by V

pn

C070

V

pn

Adapt n-controller gain

Master and slave
C054

Check current division between master and slave.

Application parameters

Master
C019

xxxx rpm

Set threshold n

act

= 0

Save parameter

Master and slave
C003

Save parameter set

Show/Hide Bookmarks

Advertising