Selection aid – Lenze EDS4900U-REG User Manual
Page 301
![background image](/manuals/566281/301/background.png)
Selection aid
15-9
48XX/49XXSHB0399
Parameter setting
Code
Input
Description
Input according to motor nameplate
Master and slave
C083
xxx A
Rated field current
C084
xxx ms
Armature-time constant
C088
xxx A
Rated motor current
C090
xxx V
Rated motor voltage
Input of current limits
Master and slave
C022, C023
xxx A
Maximum motor current
Enter controller configuration
Master and slave
C000
-2-
Extended code set
C005
-11-
Speed control with tacho feedback
Master
C110
-1-
Input selection term. 62
C111
-25-
Monitor output ’M
set
’
Adjustment of speed controller
Master and slave
C011
xxxx rpm
Select max. speed
C025
-2-
Select adjustment at terminals 3 and 4
C029
n
act
Adjust speed
Slave
C071
9999 ms
T
nn
, no I component
C025
-3-
Select adjustment at terminal 6
C027
Select weighting factor for act. speed influence divided by V
pn
C070
V
pn
Adapt n-controller gain
Master and slave
C054
Check current division between master and slave.
Application parameters
Master
C019
xxxx rpm
Set threshold n
act
= 0
Save parameter
Master and slave
C003
Save parameter set
Show/Hide Bookmarks