Configuration

7-121

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

C011

n

max

speed

3000

rpm

250 rpm

{1rpm}

5000 rpm

n

max

is the reference for the analog and

relative setpoint selection as well as for
the acceleration and deceleration times.
Parameter setting via interface:
Inhibit the controller before substantial
parameters changes.

C012

Acceleration
time T

ir

for main

setpoint

0.00s

0.00 s

{0.01 s}

1 s

1 s

{0.1 s}

10 s

10 s

{1 s}

100 s

100 s

{10 s}

990 s

Time refers to 0...n

max

C013

Deceleration
time T

if

for main

setpoint

0.00s

0.00 s

{0.01 s}

1 s

1 s

{0.1 s}

10 s

10 s

{1 s}

100 s

100 s

{10 s}

990 s

Time refers to 0...n

max

C017*

Threshold
n

act

ˆ n

x

-3000

rpm

-5000 rpm

{1 rpm}

+ 5000 rpm

If the actual speed falls below the
comparison speed n

x

, the corresponding

output will be activated.

C019*

Threshold
n

act

= 0

50 rpm 0 rpm

{1 rpm}

5000 rpm

If the actual speed falls below the
threshold, the corresponding output will
be activated.

C022

+ I

max

limit

Rated

control-

ler cur-

rent

Current limit of thyrister bridge 1
0

{0.1A}

100A

100A

{1A}

1200A

Current limit depends on controller:
29A

(4902)

45A

(4903)

90A

(4904)

150A (4905)
240A (4906)

C023

-I

max

limit

Current limit of thyrister bridge 2

0

{0.1A}

100A

100A

{1A}

1200A

(

)

300A (4907)
400A (4X08)
600A (4X09)
840A (4X11)
1200A (4X12)
1350A (4X13)

C025

¤ Input selection:

Input
adjustment

2

-1-

Terminals X1/1, X1/2

-2-

Terminals X1/3, X1/4

-3-

Terminal X1/6

-4-

Terminal X1/8

-5-

Armature voltage feedback

-10

Digital frequency input X5

-11-

Digital frequency input X9

-12-

Resolver X7

-13-

Encoder output X8

Select (under C025) the input which is to
be adjusted with C026, C027, C028 or
C029.