L-force | plc designer – Lenze PLC Designer PLC Designer (R2-x) User Manual

Page 26

Advertising
background image

L-force | PLC Designer

Lenze specifications

24

DMS 3.2 EN 02/2011 TD29



2.1.2

Updating the Lenze target "V5 Logic with Motion" to "V6 Logic with Motion"

Step

V5 Logic with Motion-> V6 Logic

V5 Logic with Motion- > V6 Logic with Motion

1

Do not convert, as Motion components are lost
during conversion to the Logic target!

Open org. V5 project

2

Set "Save configuration files in project“

option

3

Save project

4

Select the V6 target under Target system
settings Ω Configuration

5

Add the following function libraries in the
Library manager to the project:

3S_CANOpenMaster.lib

SM_CANWatch.lib

SM_CAN.lib und

LenzeCANdrive.lib

6

Remove
the\Motion\Drives\CAN\3S_CanDrv.lib
function library from the project in the Library
manager

7

Add the 3S_CanDrv.lib function library to the
project in the Library manager

8

Save and close project

9

Open project

10

Translate project completely

Possibly incompatibilities are caused by new
lib versions which then have to be
individually edited manually.

Example: In contrast to the version from the
V5 target, the SMC_Interpolator FB from the
V6 target has two basic inputs.

2.1.3

Updating the Lenze target "V6 Logic" to "V6 Logic with Motion"

Step

V6 Logic -> V6 Logic with Motion

1

Open org. V6 Logic project

2

Select the V6 Logic + Motion Target under Target system settings Ω Configuration

3

Translate project completely