L-force | PLC Designer

PLC Designer Visualization



DMS 3.2 EN 02/2011 TD29

713

20.6.14

Input

Dialog for configuring the visualization elements (Category Input)

Toggle variable: If this option is activated, in online mode you will toggle the value of
the variables which are located in the input field by each mouse click on the
visualization element. You can obtain input assistance for data entry via <F2>.

The

value of the Boolean variable changes with each mouse click from TRUE to FALSE and
then back to TRUE again at the next mouse click, etc.

Tap Variable: If this option is activated, in online mode you can switch the value of the
Boolean variable which is located in the input field, between TRUE and FALSE. Place
the mouse cursor on the element, press the mouse-key and hold it depressed. If option
Tap FALSE is activated, the value is set to FALSE as soon as the mouse key is pressed,

otherwise it is set to TRUE at this moment. The variable changes back to its initial
value as soon as you release the mouse key.

Zoom to Vis...: If this option is activated, you can enter in the edit field the name of a

visualization object of the same project to which you want to jump by a mouse-click
on the element in online mode. In this case always first the window of the target
visualization will be opened before that of the current one will be closed.