L-force | plc designer – Lenze PLC Designer PLC Designer (R2-x) User Manual

Page 628

Advertising
background image

L-force | PLC Designer

Compiler Errors and Warnings

626

DMS 3.2 EN 02/2011 TD29



4410

"Called POU not in project."

Import the called POU.

4411

"Error in global variable list."

Please check the SEQ file.

4412

"Internal error no.11"

Please contact the PLC manufacturer.

4413

"Error in format of line in data block"

In the code which should be imported there is an erroneous date.

4414

"FB/FX name missing."

In the original S5D file the symbolic name of an (extended) POU is missing.

4415

"Instruction after block end not allowed."

A protected POU cannot get imported.

4416

"Invalid command"

The S5/S7 command´cannot be disassembled.

4417

"Comment not closed"

Close the comment with "*)".