L-force | PLC Designer

Compiler Errors and Warnings



DMS 3.2 EN 02/2011 TD29

577

1970

"Parameter manager: List '<Name>' , Column '<Name>', Value '<Name>' could not be
imported!"

Check the Import-file *.prm for entries which do not match the current configuration
(standard values resp. XML-description file) of the Parameter Manager.

1980

Global network variables '<Name>' '<Name>': simultaneous reading and writing may
result in loss of data!"

In the configuration of the network variables list (Select list in the Resources tab and
open dialog 'Global variables list' via command 'Properties' in the context menu)
options 'Read' and 'Write' are activated. Regard that this might result in data losses
during communication.

1990

"No 'VAR_CONFIG' for '<name>'"

For this variable there is no address configuration available in the
Variable_Configuration (VAR_CONFIG). Open window Variable_Configuration in the

Resources tab and there insert the appropriate configuration (Command 'Insert 'All
instance paths').

2500

"Task '<task name>': fno cycle time specified for cyclic task"

In the Task configuration a cyclic task has been created, for which no cycle time has
been defined. Enter an appropriate time span in dialog 'Taskattributes' at "Interval".

4710

"'<name>' ('<number>'): A required expression has not been configured"

Check the configuration of the slider element in category 'Variables': There must be
defined a valid value for each of the fields 'Min.Value', 'Slider' and 'Max. Value'.

4711

"'<name>'('<number>'): The slider element is not supported by your
SysLibTargetVisu."

Install and use the current version of the library SysLibTargetVisu.library.