L-force | plc designer – Lenze PLC Designer PLC Designer (R2-x) User Manual

Page 302

Advertising
background image

L-force | PLC Designer

Editors in PLC Designer

300

DMS 3.2 EN 02/2011 TD29



'Insert' 'Input'

Symbol:

Shortcut: <Ctrl>+<U>

This command inserts an operator input. With many operators, the number of inputs
may vary. (For example, ADD can have 2 or more inputs.)

In order to extend such an operator by an input, you need to select the input in front
of which you wish to insert an additional input (Cursor Position 1); or you must select
the operator itself (Cursor Position 3), if a lowest input is to be inserted (see 'Cursor
positions in FBD').

The inserted input is allocated with the text "???". This text must be clicked and
changed into the desired constant or variable. For this you can also use the Input
Assistant. For the possibility to enter an address instead of the variable name please
regard the description of the options dialog in Chapter: Comments, Linebreaks,
'Extras' 'Options'.

'Insert' 'Output'

Symbol:

This command inserts an additional assignment into an existing assignment. This
capability serves the placement of so-called assignment combs; i.e., the assignment of
the value presently located at the line to several variables.

If you select the lined cross above an assignment (Cursor Position 5) (see 'Cursor

positions in FBD') or the output directly in front of it (Cursor Position 4), then there will
be another assignment inserted after the ones already there.

If the line cross directly in front of an assignment is selected (Cursor Position 4), then
another assignment will be inserted in front of this one.

The inserted output is allocated with the text "???". This text must be clicked and
changed into the desired variable. For this you can also use the Input Assistant. For the
possibility to enter an address instead of the variable name please regard the
description of the options dialog in Chapter Comments, Linebreaks, 'Extras' 'Options'.

Advertising