General remarks concerning plc-browser operation, L-force | plc designer – Lenze PLC Designer PLC Designer (R2-x) User Manual

Page 457

Advertising
background image

L-force | PLC Designer

The Resources



DMS 3.2 EN 02/2011 TD29

455

8.13.1

General remarks concerning PLC-Browser operation

Select the entry PLC-Browser in the Resources tab-control. It will be available there if it
is activated in the current target settings (category networkfunctionality).

The PLC Browser window

The browser consists of a command entry line and a result/display window.

In a selection box the input line displays a list of all the commands entered since the
start of the project (input history). They are available for re-selection until the project
is closed. Only commands, which differ from those already existing, are added to the
list.

The entered command is sent to the controller with <Enter>. If there is no Online
connection, the command is displayed in the result window in the same way as it is
sent to the controller, otherwise the response from the controller is shown there. If a
new command is sent to the controller, the content of the result window is deleted.

Commands can be entered in the form of command strings , the use of macros is
possible as well.