L-force | PLC Designer

The Resources



DMS 3.2 EN 02/2011 TD29

357

The module – except for BusMemberID – uses the same input and output
parameters. The parameters STATE and EXTENDEDINFO however have the
following, different meaning:

STATE:INT;

If READY = TRUE then STATE gets one of the following values
which define the actual bus state:

BUSSTATE_BUSOK (Bus is running correctly)

BUSSTATE_BUSFAULT (Bus error)

BUSSTATE_BUSNOTCOMMUNICATING (Communication error)

BUSSTATE_BUSSTOPPED (Bus is stopped)

EXTENDEDINFO:ARRAY[0..129] OF
BYTE;

Manufacturer specific diagnosis data of the bus member; only
the first three bits of the byte are used:

Bit 0: bus member is configured

Bit 1: bus member is active

Bit 2: bus member reports an error, detailled information can
be get via DiagGetState() *)

Module parameters / Custom parameters of an I/O Module

Module parameters Dialog

In this dialog the parameters which are given by the device file are shown. Only the
column 'value' is editable.

Index: The Index is a consecutive digit (i), which numbers through all the way the
parameters of the module.

Name: Name of the parameter