15 timing, 1 overview, 2 cuelist times – LSC Lighting CLARITY LX Series v.1 User Manual

Page 107: 3 cue times, 1 intensity fade out times

Advertising
background image

Clarity

Timing

Operator Manual

Page 97

15 Timing

15.1 OVERVIEW
Clarity provides comprehensive controls for the timing of your Cuelists and Cues. Timing

information can be entered either when recording a cue, in the Control Booth Window or when
editing a cue. Time Presets and Freesets allow you to create building blocks of timing patterns
for use in programming or to use them in live playback from the Palettes window.

15.2 CUELIST TIMES
Each cue-list can be programmed with the following time settings:

Activate (fade in) time. Default time = 0 seconds. This is the time taken for a Cue-list to
fade in when the first cue is played. Normally this would be left at 0, and the affected

fixtures in cue 1 would fade in over their programmed time for that cue. However, you
can enter an activate time to scale the fade in over time. This is most useful with chases

or when cues are set to automatically follow each other.

Release (fade out) time. Default time = 2 seconds. This the time taken for the Cue-list
to fade out when released from a Playback.

Playback Rate. Proportionally changes all of the timing information in a cue-list. By
default it is set to 100%. The range is 1 to 1000. For Example: If Rate is set to 50% it

slows all of the fades (all times are doubled). 100% = no change to rates.

See Section 25.2 for more details on cuelist times.

15.3 CUE TIMES
The way that each cue in the cue-list is played can be set as either:

Halt. The cue is manually played by its GO button

Follow. The cue is automatically played after the previous cue finishes. In the Control
Booth, select the cue then click on “Halt” to reveal the drop down box and select

“Follow”.

Wait time. The cue is automatically played after a wait time after the previous cue

finishes. To set a wait time, in the Control Booth, select the cue then click on “Halt” or
“Follow” to highlight it then type in a wait time in seconds.


The default setting for “Wait” is to “Halt” so that at the conclusion of the previous cue, the

cue-list will wait until the “Halt” cue is manually played.


Wait times can also be set in the “Record Cue” dialogue box, in the Performance window or by

editing a cue and right clicking on the cue at the bottom of the Programmer window.

Every attribute in every cue can have individual values for:

Delay. The time from when the cue starts until the attribute(s) begin to change. The

default delay time is 0 seconds.

Fade. The time taken for the attribute(s) to change to the value in the cue. The default

fade time is 2 seconds.

These attribute times as fully described below.

15.3.1 Intensity Fade Out times.

In the Control Booth window you can set specific fade out times for any intensity parameters in
each cue.

Advertising
This manual is related to the following products: