Chapter 3
Offset Tables and Setup

3-30

(softkey level 2)

PRGRAM

PARAM

AMP

DEVICE

SETUP

MONI-

TOR

TIME

PARTS

PTOM

SI/OEM

SYSTEM

TIMING

3.

Press the {AXIS PARAM} softkey.

(softkey level 3)

AXIS

PARAM

PATCH

AMP

UPDATE

BACKUP

UPLD/

DWNLD

BACKUP

AMP

4.

Press the {RANGE PARAM} softkey.

(softkey level 4)

SPNDL

PARAM

SERVO

PARAM

AXIS

CALIB

HOME

CALIB

REVERS

ERROR

RANGE

PARAM

Your system installer initially sets these values in AMP. You can modify
them with online AMP by using this screen:

REPLCE

VALUE

ADD TO

VALUE

UPDATE

& EXIT

QUIT

MAXIMUM +/-- WEAR RADIUS
MAXIMUM +/-- GEOM RADIUS

X AXIS

MAXIMUM WEAR OFFSET CHANGE
MAXIMUM GEOM OFFSET CHANGE
MAXIMUM +/-- WEAR OFFSET
MAXIMUM +/-- GEOM OFFSET

NEXT

AXIS

OFFSET RANGE VERIFICATION

Per table values

Per axis values

[inch]

.12345
10.12345

[inch]

.01000
1.00000
.10000
10.00000