2 scaling magnification data screen – Rockwell Automation 8520-GUM 9/Series CNC Grinder Operation and Programming Manual Documentation Set User Manual

Page 368

Advertising
background image

Coordinate Control

Chapter 11

11-52

The scaling magnification data screen lists the currently active scaling
magnification amount, the current center of scaling, and the default scaling
magnification amount for all axes. The currently active scaling
magnification amount and the current center of scaling for the axes can
only be monitored through this screen. The default scaling magnification
amount for the axes can be monitored or changed through this screen.

You should only change the default scaling magnification values when the
control is in a stopped state. If you change the default values, the new
default values do not become active until the control executes the next
G14.1 block.

Access the scaling magnification data screen through these steps:

1.

Press the {OFFSET} softkey on the main menu screen.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

2.

Press the {SCALNG} softkey to display the scaling magnification
data screen:

(softkey level 2)

WORK

CO-ORD

WHEEL

GEOMET

RADIUS

TABLE

DRESSR

TABLE

SCALNG

COORD

ROTATE

BACKUP

OFFSET

11.11.2
Scaling Magnification Data
Screen

Advertising