2 scaling magnification data screen – Rockwell Automation 8520-GUM 9/Series CNC Grinder Operation and Programming Manual Documentation Set User Manual
Page 368

Coordinate Control
Chapter 11
11-52
The scaling magnification data screen lists the currently active scaling
magnification amount, the current center of scaling, and the default scaling
magnification amount for all axes. The currently active scaling
magnification amount and the current center of scaling for the axes can
only be monitored through this screen. The default scaling magnification
amount for the axes can be monitored or changed through this screen.
You should only change the default scaling magnification values when the
control is in a stopped state. If you change the default values, the new
default values do not become active until the control executes the next
G14.1 block.
Access the scaling magnification data screen through these steps:
1.
Press the {OFFSET} softkey on the main menu screen.
(softkey level 1)
PRGRAM
MANAGE
OFFSET MACRO
PARAM
QUICK
CHECK
SYSTEM
SUPORT
FRONT
PANEL
ERROR
MESAGE
PASS-
WORD
SWITCH
LANG
2.
Press the {SCALNG} softkey to display the scaling magnification
data screen:
(softkey level 2)
WORK
CO-ORD
WHEEL
GEOMET
RADIUS
TABLE
DRESSR
TABLE
SCALNG
COORD
ROTATE
BACKUP
OFFSET
11.11.2
Scaling Magnification Data
Screen