Running a Program

Chapter 7

7-19

If you want to use the graphics feature, see page for QuickCheck with
graphics. To use the QuickCheck feature as described below without
graphics, the graphics option must be disabled.

To use the QuickCheck feature:

1.

Select a program to check as described on page 7-6 and return to
softkey level 1.

2.

Press the

{QUICK CHECK}

softkey.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

When you press the

{QUICK CHECK}

softkey, the QuickCheck

appears in reverse video and prompts the graphics option.

3.

Press the

<CYCLE START>

button. The control executes program

blocks as fast as it can process.

If a program block is found that contains an error, the program check stops
and the control displays the message “ERROR FOUND.”

To continue checking the remaining program blocks, press the

<CYCLE START>

button again. If no more errors are found, the control

displays the message “COMPLETED WITH ERROR (S)” and the part
program is automatically deactivated to allow editing.

If the control finds no errors during QuickCheck, the program screen
displays the message “COMPLETED WITH NO ERRORS.” The control
then automatically resets the program to the first block.

To disable QuickCheck:

Press:

without the graphics option

the {QUICK CHECK} softkey again

with the graphics option

the {QUICK CHECK} softkey
followed by the {STOP CHECK}
softkey

Advertising