Program Interrupts and
Dressing Interrupts

Chapter 22

22-9

Example 22.1

Enabling and Disabling the Interrupt Features

N1M96L0P11111;

Enables program O11111 as a type 1 interrupt and allows it to be
executed when the interrupt signal from switch 0 is received.

N2M96L1P12345;

Enables program O12345 as a type 2 interrupt and allows it to be
executed when the interrupt signal from switch 1 is received.

N3M96L3P11111;

Enables program O11111 as a type 2 interrupt and allows it to be
executed when the interrupt signal from switch 3 is received. This is
the same program as selected for type 0 interrupts.

N4M97L3;

Disables any interrupt program that is called by switch 3. Any signal
to execute an interrupt from switch 3 is ignored after this block is
executed unless reactivated with a M96L3 block.

N5M96L3;

Re-enables interrupt program called by switch 3. Since no P word is
programmed in this block, the last programmed P word (enabling
program O11111) is active.

N5M96L0P22222;

Alters the program that is called for the interrupt with switch 0. The
new program called when the interrupt signal is received is O22222.

N6M97L0;

Disables interrupt switch 0.

N7M97L1;

Disables interrupt switch 1.

Important: All program interrupts that are enabled in a part program are
automatically disabled by the control when either an end-of-program (M02
or M30) block is read, a new program is selected as active, or a control
reset is performed.

Advertising