Rockwell Automation 8520-GUM 9/Series CNC Grinder Operation and Programming Manual Documentation Set User Manual

Page 296

Advertising
background image

Introduction to Programming

Chapter 10

10-18

Table 10.A

How the Control Interprets Numeric Values

Position Interpreted by the control

Programmed X Value

TZS Disabled
LZS Disabled

TZS Disabled

LZS Enabled

TZS Enabled

LZS Disabled

X123456.

ERROR

ERROR

ERROR

X12345.6

12345.60

12345.60

12345.60

X1234.56

1234.56

1234.56

1234.56

X123.456

123.45

123.45

123.45

X12345

12345.00

123.45

12345.00

X012345

ERROR

123.45

1234.50

X123456

ERROR

1234.56

12345.60

X1234567

ERROR

12345.67

12345.67

X12345678

ERROR

ERROR

ERROR

Important: If backing up a table using a G10 program (such as the offset
tables or coordinate system tables), keep in mind the G10 program output
is generated in the current format of the control (LZS or TZS). If you
intend to transport this table to a different machine it must also be using the
same format.

Your system installer can also set an AMP parameter to generate an error
or use a value of zero for characters that are programmed without numeric
values. If this AMP feature is disabled, programming:

GX;

rapid move to X zero

M;

program stop

would result in the actions described in the comments following the blocks.
If you enable the feature, the error “NUMERIC MISSING” would have
occurred upon execution of either of those blocks.

In alphabetical order, Table 10.B shows the addresses for words that are
recognized by the control, their typical formats, and their general
meanings. Since most of these formats are configured in AMP, see the
documentation prepared by your system installer.

You can alter many of the addresses themselves in AMP. This table
assumes the most common names (such as X and Z for the main axes).
Alterable addresses are indicated by the note “AMP assigned”.