Chapter 3
Offset Tables and Setup

3-31

About the Offset Range Verification Screen

on a grinder, range checking units for this screen are always RADIUS,
regardless of the program/control mode

display format is fixed

Mode

Places to the left of the decimal point

Places to the right of the decimal point

inch

3

5

metric

4

5

data entry is bounded by the programming resolution of the axes

When Does Verification Occur

Verification occurs when a value enters the table from:

data entry screens

PAL

paramacros

Important: The control does not perform the verification if the value, old
or new, is zero, nor does it check G10 data-setting codes.

Verify for Maximum Value

This value represents the absolute maximum value per table for all tool
offsets in that table.

If you enter:

then:

a positive number greater than the maximum value

the control generates the error message:
“OFFSET EXCEEDS MAX VALUE”

a negative number less than the negative of the
maximum value

The control does not modify the value in
the table.

Verify for Maximum Change

This change represents the amount an offset may change from its current
value. If you exceed the amount set by the system installer in AMP, the
change is not allowed. The control generates the error message “OFFSET
EXCEEDS MAX CHANGE.”

END OF CHAPTER