Rockwell Automation 8520-GUM 9/Series CNC Grinder Operation and Programming Manual Documentation Set User Manual
Page 672

Paramacros
Chapter 20
20-28
#5095 and 5096
Probe Length and Radius
Probe tip radius and probe length are defined by your system installer in
AMP. These values can also be changed by using these paramacro system
parameters:
5095
Length of Probe -- used primarily for G37 operations. This distance is measured along
the axis being probed. For example, if an X-axis probing operation is being performed
(as shown in the following figure) then the value entered here is the length of the probe
on the X-axis. The length is measured from the tool gauge point to the center of the
probe radius.
5096
Radius of Probe -- used for either G31 or G37 operations. This parameter defines the
radius of the probe tip. If the documentation for your probe lists a tip diameter, enter half
of that value.
Figure 20.1 shows how these parameters are typically used.
Figure 20.1
Typical Tool Gauging Configurations
Probe
Probe
radius
Probe
Probe
radius
Probe
Probe
radius
Probe
length
Case 1
Case 2
Case 3
+ Z
--X
--X
12079-I
See chapter 19 for details on probing operations.