2 limitations – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 110

Advertising
background image

4.3 Test Without Motor Function

4-27

Operation

4.3.2 Limitations

The following functions cannot be used during the test without motor.

• Regeneration and dynamic brake operation
• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the Sig-

maWin+.)

• Items marked with “X” in the following utility function table.

: can be used

× : cannot be used

Fn No.

Contents

Can be

used or not

Motor not

connected

Motor

connected

Fn000

Alarm history display

Fn002

JOG operation

Fn003

Origin search

Fn004

Program JOG operation

Fn005

Initializing parameter settings

Fn006

Clearing alarm history

Fn008

Absolute encoder multi-turn reset and encoder alarm reset

×

Fn00C

Offset adjustment of analog monitor output

Fn00D

Gain adjustment of analog monitor output

Fn00E

Automatic offset-signal adjustment of motor current detection signal

×

Fn00F

Manual offset-signal adjustment of motor current detection signal

×

Fn010

Write prohibited setting

Fn011

Servomotor model display

Fn012

Software version display

Fn013

Multi-turn limit value setting change when a multi-turn limit disagreement alarm
occurs

×

Fn014

Resetting configuration error of option module

Fn01B

Vibration detection level initialization

×

×

Fn01E

Display of SERVOPACK and servomotor ID

Fn01F

Display of servomotor ID in feedback option

Fn020

Origin setting

×

Fn030

Software reset

Fn200

Tuning-less level setting

×

×

Fn201

Advanced autotuning

×

×

Fn202

Advanced autotuning by reference

×

×

Fn203

One-parameter tuning

×

×

Fn204

Anti-resonance control adjustment function

×

×

Fn205

Vibration suppression function

×

×

Fn206

EasyFFT

×

×

Fn207

Online vibration monitor

×

×

Advertising