26 (2) safety input circuit – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 70

Advertising
background image

3 Wiring and Connection

3.4.1 Sequence Input Circuits

3-26

(2) Safety Input Circuit

As for wiring input signals for safety function, input signals make common 0 V. It is necessary to make an

input signal redundant.

Input Signal Connection Example

24-V power supply

Switch

Fuse

SERVOPACK

/HWBB1+ 4

3

/HWBB1-

/HWBB2+

/HWBB2-

3.3 k

Ω

CN8

3.3 k

Ω

6

5

3.3 k

Ω

3.3 k

Ω

Advertising