Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 218

Advertising
background image

6 Utility Functions (Fn

)

6-16

3

Press the

or

Key to adjust the offset of CH1

(torque reference monitor).
Adjust the offset so that the measurement instrument
reading is as close to 0 V as possible.

4

After the offset adjustment of CH1 has completed,

Press the

Key. The cursor moves to CH2 side.

5

Press the

or

Key to adjust the offset of

CH2.
Adjust the offset so that the measurement instrument
reading is as close to 0 V as possible.

6

After having completed the offset adjustment both for
CH1 and CH2, press the

Key.

The adjustment results are saved in the SERVO-

PACK. “DONE” is displayed in the status display
after saving is completed.

7

Press the

Key to return to the Utility Function

Mode main menu.

(cont’d)

Step

Display Example

Keys

Description