Three-phase 400 v, sgdv- d – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 51

Advertising
background image

3.1 Main Circuit Wiring

3-7

Wiring and Connection

• SGDV-470A, 550A, 590A, 780A

Three-phase 400 V, SGDV-

D

SGDV-1R9D, 3R5D, 5R4D, 8R4D, 120D, 170D

2KM

L1

ENC

U

V

W

M

0 V

1Ry

ALM+

ALM

3

4

1D

B2

L2

CN1

1KM

L1C

L3

L2C

1QF

R S T

1FLT

+24 V

3SA

B1/

1Ry

1PL

1KM

2KM

1SA

1Ry

1KM

2SA

1KM

SGDV-

A

Regenerative
resistor unit

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

SERVOPACK

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

ENC

U

V

W

M

0 V

1Ry

ALM+

ALM

3

4

1D

CN1

1QF

R S T

1FLT

+24 V

3SA

B2
B3

1

2

B1/

1Ry

1PL

1KM

2KM

1SA

1Ry

1KM

2SA

L1

2KM

L2
L3

24V

+

1KM

0V

1KM

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

SGDV-

D

DC power

supply

(24V)

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

SERVOPACK

Advertising