3.1 Main Circuit Wiring

3-11

Wiring and Connection

470A, 550A

• Available rated current for molded-case circuit breaker: 60 A or less
• Available rated current for non-time delay fuse or time delay fuse: 60 A or

less

590A, 780A

• Available rated current for molded-case circuit breaker: 100 A or less
• Available rated current for non-time delay fuse or time delay fuse: 100 A

or less

(Available rated current for class J non-time delay or faster fuse: 125 A or
less)

210D, 260D

• Available rated current for molded-case circuit breaker: 60 A or less
• Available rated current for non-time delay fuse: 60 A or less
• Available rated current for time delay fuse: 35 A or less

280D, 370D

• Available rated current for molded-case circuit breaker: 80 A or less
• Available rated current for non-time delay fuse: 125 A or less
• Available rated current for time delay fuse: 75 A or less

(cont’d)