Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual
Page 55

3.1 Main Circuit Wiring
3-11
Wiring and Connection
470A, 550A
• Available rated current for molded-case circuit breaker: 60 A or less
• Available rated current for non-time delay fuse or time delay fuse: 60 A or
less
590A, 780A
• Available rated current for molded-case circuit breaker: 100 A or less
• Available rated current for non-time delay fuse or time delay fuse: 100 A
or less
(Available rated current for class J non-time delay or faster fuse: 125 A or
less)
210D, 260D
• Available rated current for molded-case circuit breaker: 60 A or less
• Available rated current for non-time delay fuse: 60 A or less
• Available rated current for time delay fuse: 35 A or less
280D, 370D
• Available rated current for molded-case circuit breaker: 80 A or less
• Available rated current for non-time delay fuse: 125 A or less
• Available rated current for time delay fuse: 75 A or less
(cont’d)
SERVOPACK
Model SGDV-
Restrictions