3 Wiring and Connection

3.8.1 Wiring for Noise Control

3-36

(1) Noise Filter

The SERVOPACK has a built-in microprocessor (CPU), so protect it from external noise as much as possible

by installing a noise filter in the appropriate place.

The following is an example of wiring for noise control.

∗1. For ground wires connected to the ground plate, use a thick wire with a thickness

of at least 2.0 mm

2

(preferably, plain stitch cooper wire).

∗2.

should be twisted-pair wires.

∗3. When using a noise filter, follow the precautions in 3.8.2 Precautions on Con-

necting Noise Filter.

(2) Correct Grounding

Take the following grounding measures to prevent the malfunction due to noise.

Grounding the Motor Frame

Always connect servomotor frame terminal FG to the SERVOPACK ground terminal . Also be sure to
ground the ground terminal .

If the servomotor is grounded via the machine, a switching noise current will flow from the SERVOPACK

main circuit through servomotor stray capacitance. The above grounding is required to prevent the adverse

effects of switching noise.

Noise on the I/O Signal Line

If the I/O signal lines are affected by noise, ground the 0 V (SG) terminal of I/O signal. If the main circuit wir-

ing for the motor is in a metal conduit, ground the conduit and its junction box. For all grounding, ground at
one point only.

U

W

V

L2

L1

L3

L2C

L1C

CN2

CN1

ENC

(FG)

M

SERVOPACK

Operation relay
sequence
Signal generation
circuit (not included)

Noise
Filter

DC

power

(Ground plate)

2.0 mm
min.

2

200 VAC

Noise filter *3

*1

*3

*2

2.0 mm

2

min .

Ground: Ground to an independent ground

2.0 mm min.

2

*1

Servomotor