4.5.3 Battery Replacement

4-36

4.5.3 Battery Replacement

If the battery voltage drops to approximately 2.7 V, an absolute encoder battery error (A.830) or absolute

encoder battery warning (A.930) will be displayed.

If an alarm or warning is displayed, replace the battery using the following procedure.

Use Pn008 to set either an alarm (A.830) or a warning (A.930).

• If Pn008.0 is set to 0, an ALM signal is sent for a maximum of 5 seconds, and then the battery voltage is

checked for 4 seconds when the power is turned ON.

Note: After those initial 4 second, no alarm will be displayed even if the battery voltage drops to approximately 2.7 V.

• If Pn008.0 is set to 1, the battery voltage will constantly be monitored.

(1) Battery Replacement Procedure

Using an Encoder Cable with a Battery Case

1. Turn ON only the SERVOPACK control power supply.
2. Open the battery case cover. (Example: cable with battery and connectors at both ends)

Parameter

Meaning

When Enabled Classification

Pn008

n.

0

Outputs the alarm A.830 when the battery voltage
drops. [Factory setting]

After restart

Setup

n.

1

Outputs the warning A.930 when the battery voltage
drops.

4 s

Max 5 s

Warning A.930
(Pn008.0 = 1)

Alarm A.830
(Pn008.0 = 0)

ALM

OFF (close)

Alarm status

Normal status

ON (open)

Battery

voltage being

monitored

Battery voltage

being monitored

Control
power

Open the cover.