3.1 Main Circuit Wiring

3-17

Wiring and Connection

3.1.5 Using More Than One SERVOPACK

This section shows an example of the wiring when more than one SERVOPACK is used and the precautions.

(1) Wiring Example

Connect the alarm output (ALM) terminals for the three SERVOPACKs in series to enable alarm detection

relay 1Ry to operate.

When the alarm occurs, the ALM output signal transistor is turned OFF.

(2) Precautions

Multiple servos can share a single molded-case circuit breaker (1QF) and a noise filter. Always select a 1QF

and a noise filter that has enough capacity for the total power capacity (load conditions) of those servos.

1KM

R S

T

1QF

2KM

1Ry

+24 V

L1
L2
L3

L1C

CN1

CN1

CN1

3

ALM+

4

ALM -

0 V

L2C

1FLT

M

L1
L2
L3

3

ALM+

4

ALM -

L1
L2
L3

L1C

ID

3

ALM+

4

ALM -

L2C

M

M

L1C

L2C

3SA

1KM

1Ry

1PL

1KM

2KM

1SA

1Ry

1KM

2SA

SERVOPACK

Servomotor

Servomotor

Servomotor

Relay

terminal

Relay

terminal

Relay

terminal

1QF:
1FLT:
1KM: Magnetic contactor
(for control power supply)
2KM:
(for main power supply)
1Ry:
1PL:
1SA:
2SA:
3SA:
1D:

Molded-case circuit breaker
Noise filter

Relay

Magnetic contactor

Indicator lamp
Surge absorber

SERVOPACK

SERVOPACK

Surge absorber
Surge absorber
Flywheel diode

supply ON

Power supply

Relay
terminal

(For servo alarm

display)

Servo power

supply OFF

Servo power

Advertising