4 origin search (fn003), Caution, 1) settings before operation – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 208: 2) operating procedure

Advertising
background image

6 Utility Functions (Fn

)

6-6

6.4 Origin Search (Fn003)

The origin search is designed to position the origin pulse position of the incremental encoder (phase-C) and to

clamp at the position.

This mode is used when the motor shaft needs to be aligned to the machine.
Motor speed at the time of execution: 60 min

-1

(For SGMCS direct drive motors, the speed at the time of execution is 6 min

-1

)

(1) Settings before Operation

The following settings are required before performing an origin search.

• If a servo ON command is input, send a servo OFF command.

(2) Operating Procedure

Follow the steps below to execute the origin search.

CAUTION

• Perform origin searches without connecting the coupling.

The forward run prohibited (P-OT) and reverse run prohibited (N-OT) signals are not effective in origin

search mode.

For aligning the motor

shaft with the machine

Servomotor

Machine

Step

Display Example

Keys

Description

1

Press the

Key to open the Utility Function Mode

main menu and select Fn003.

2

Press the

Key. The display is switched to the

execution display of Fn003.
Note:If the display is not switched and “NO-OP” is

displayed in the status display, change the fol-
lowing settings. (Refer to 6.12.)
• If Write Prohibited is set in Fn010:

→ Cancel the Write Prohibited setting.

• If a servo ON command is input:

→ Send a servo OFF command.

3

Press the

Key.

“RUN” is displayed in the status display, and power
is applied to the servomotor.
Note: If the servomotor is already at the zero position,

“-Complete-” is displayed.