4.2 Settings for Common Basic Functions

4-11

Operation

4.2.5 Encoder Output Pulses

Encoder output pulse is the signal which processes the encoder output inside the SERVOPACK and then out-

puts externally in the form of 2-phase pulses (phase A and B) with 90

° phase differential. It is used as the feed-

back of position.

Signals and output phase form are as shown below.

(1) Signals

(2) Output Phase Form

Note: The pulse width of the (Phase C origin pulse) changes according to the setting of the Pn212 and becomes the same

as that for phase A.
Even in reverse rotation mode (Pn000.0 = 1), the output phase form is the same as that for the standard setting
(Pn000.0 = 0).

Type

Signal

Name

Connector

Pin Number

Name

Remarks

Output

PAO

CN1-17

Encoder output pulse: phase A

Output pulses per motor rotation set
in the encoder output pulses (Pn212),

and phase A and phase B are different
from each other in phase by an elec-
tric angle of 90

°.

/PAO

CN1-18

Encoder output pulse: phase /A

PBO

CN1-19

Encoder output pulse: phase B

/PBO

CN1-20

Encoder output pulse: phase /B

PCO

CN1-21

Encoder output pulse: phase C

One pulse is output per motor rota-
tion.

/PCO

CN1-22

Encoder output pulse: phase /C

ENC

CN1 CN2

SERVOPACK

Host controller

Serial

data

PAO

PBO

PCO

Converts
serial data to
pulse.

Dividing

circuit

(Pn212)

If using the SERVOPACK’s phase-C pulse output for a zero point return, rotate the ser-
vomotor twice before starting a zero point return. If the configuration prevents the servo-
motor from returning to the zero point by rotating the servomotor twice, perform a zero
point return at a motor speed of 600 min

-1

or below. If the motor speed is faster than 600

min

-1

, the phase-C pulse output may not be output correctly.

Phase A

Phase B

Phase C

90°

t

Phase A

Phase B

Phase C

t

Forward rotation (phase B leads by 90°) Reverse rotation (phase A leads by 90°

90°