3 Wiring and Connection

3.1.2 Using a Standard Power Supply Input (Single-phase 100-V, Three-phase 200-V, or Three-phase 400-V)

3-8

• SGDV-210D, 260D, 280D, 370D

ENC

U

V

W

M

0 V

1Ry

ALM+

ALM

3

4

1D

CN1

1QF

R S T

1FLT

+24 V

3SA

B2

1

2

B1/

1Ry

1PL

1KM

2KM

1SA

1Ry

1KM

2SA

L1

2KM

L2
L3

24V

+

1KM

0V

1KM

SGDV-

D

DC power
supply
(24 V)

Regenerative
resistor unit

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

SERVOPACK

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

Advertising