4.6.2 External Device Monitor (EDM1)

The external device monitor (EDM1) functions to monitor failures in the HWBB function. Connect the moni-

tor to feedback signals to the safety unit. The relation of the EDM1, /HWBB1, and /HWBB2 signals is shown

below.

Failure Detection Signal for EDM1 Signal

Detection of failures in the EDM1 circuit can be checked using the status of the 3 signals in the table. Failures
can be detected if the failure status can be confirmed, such as when the power supply is turned ON.

Signal

Name

Logic

/HWBB1

ON

ON

OFF

OFF

/HWBB2

ON

OFF

ON

OFF

EDM1

OFF

OFF

OFF

ON

When both /HWBB1 and /
HWBB2 signals are OFF,

EDM1 signal turns ON.

WARNING

The EDM1 signal is not a safety output. Use it only for monitoring a failure.