5 program jog operation (fn004), 1) settings before operation, 2) related parametersf – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 210

Advertising
background image

6 Utility Functions (Fn

)

6-8

6.5 Program JOG Operation (Fn004)

The Program JOG Operation is a utility function, that allows continuous automatic operation determined by

the preset operation pattern, movement distance, movement speed, acceleration/deceleration time, waiting

time, and number of time of movement.
This function can be used to move the servomotor without it having to be connected to a host controller for the

machine as a trial operation in JOG operation mode. Program JOG Operation can be used to confirm the oper-

ation and for simple positioning operations.

(1) Settings before Operation

The following settings are required before performing a program JOG operation.

• Consider the machine operation range and safe operation when setting the movement distance and speed

correctly.

• If a servo ON command has been input, send a servo OFF command.
• The main power is supplied.
• No alarm is detected.
• The overtravel does not occur.
• HWBB function is disable.

Note:

• The functions that are applicable for position control, such as position reference filter, can be used.
• The overtravel function is enabled in this function.

(2) Related Parametersf

∗ When using an SGMCS direct drive motor, the setting unit will be automatically changed to 0.1 min

-1

Pn530

Program JOG Operation Related Switch

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0000 to 0005

0000

Immediately

Setup

Pn531

Program JOG Movement Distance

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

1 to 1073741824

1 reference unit

32768

Immediately

Setup

Pn533

Program JOG Movement Speed

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

1 to 10000

1 min

-1*

500

Immediately

Setup

Pn534

Program JOG Acceleration/Deceleration Time

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

2 to 10000

1 ms

100

Immediately

Setup

Pn535

Program JOG Waiting Time

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 10000

1 ms

100

Immediately

Setup

Pn536

Number of Times of Program JOG Movement

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 1000

1 time

1

Immediately

Setup

Speed

Position

Torque

Speed

Position

Torque

Speed

Position

Torque

Speed

Position

Torque

Speed

Position

Torque

Speed

Position

Torque

Advertising