5 absolute encoder reception sequence, 1) outline of absolute signals, 2) absolute data reception sequence – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 122: Phase-c output specifications

Advertising
background image

4.5 Absolute Encoders

4-39

Operation

4.5.5 Absolute Encoder Reception Sequence

The sequence in which the SERVOPACK receives outputs from the absolute encoder and transmits them to

host controller is shown below.

(1) Outline of Absolute Signals

The serial data, pulses, etc., of the absolute encoder that are output from the SERVOPACK are output from the
PAO, PBO, and PCO signals as shown below.

Phase-C Output Specifications

The pulse width of phase C (origin pulse) changes depending on the encoder output pulse (Pn212), becoming

the same width as phase A.

The output timing is one of the following.

• Synchronized with the rising edge of phase A
• Synchronized with the falling edge of phase A
• Synchronized with the rising edge of phase B
• Synchronized with the falling edge of phase B

Note: When host controller receives the data of absolute encoder, do not perform counter reset using the output of PCO

signal.

(2) Absolute Data Reception Sequence

1. Send the sensor ON command from the host controller.
2. After 100 ms, set the system to serial data reception-waiting-state. Clear the incremental pulse up/down

counter to zero.

3. Receive eight characters of rotational serial data.
4. The system enters a normal incremental operation state about 400 ms after the last rotational serial data is

received.

Note: The output pulses are phase-B advanced if the servomotor is turning forward regardless of the setting in Pn000.0.

Signal Name

Status

Contents

PAO

At initialization

Rotational serial data
Initial incremental pulses

Normal time

Incremental pulses

PBO

At initialization

Initial incremental pulses

Normal time

Incremental pulses

PCO

Always

Origin pulses

ENC

CN1

PAO

PBO

PCO

CN2

Serial

data

Serial data→
pulse conversion

Host
controller

SERVOPACK

Dividing

circuit

(Pn212)

Sensor ON
command

PAO

PBO

Incremental pulses

Incremental pulses

Undefined

Undefined

(Phase A) (Phase A)

(Phase B) (Phase B)

Rotational
serial data

400 ms max.

50 ms

1 to 3 ms

About 15 ms

90 ms typ.

60 ms min.

Initial
incremental
pulses

Initial
incremental
pulses

Advertising