5.8 Additional Adjustment Function

5-53

Adjustments

Relationship between the Gain Switching Waiting Time and the Switching Time Constant

In this example, the “positioning completed signal (/COIN) ON” condition is set as condition A for automatic
gain switching. The position loop gain is switched from the value in Pn102 (Position Loop Gain) to the value

in Pn106 (2nd Position Loop Gain). When the /COIN signal goes ON, the switching operation begins after the

waiting time set in Pn135. The switching operation changes the position loop gain linearly from Pn102 to
Pn106 over the switching time set in Pn131.

Note: Automatic gain switching is available in the PI and I-P controls. (Pn10B)

Switching condition A established

Gain
Switching Time

Pn131

Gain
Switching
Waiting Time

Pn135

Pn102

Position Loop Gain

Pn106
2nd Position
Loop Gain

/COIN